TM

Titanium is used in all the wet metal parts of the TM pumps. Titanium has a far stronger oxide film on its surface than stainless steel does. This prevents the pumps from being corroded in the seawater which has a very high chlorine ion concentration.

Technical Data
  • ø Discharge bore mm: 50mm
  • Type of Fluid: Sewage
  • Max. Solid Handling mm: 10
  • Max. PH Value: 3-10
  • Max. Capacity l/min: 290 - 350
  • Max. Head m: 12 - 15
  • Motor output kW: 0,4 - 0,75
  • Phase / Voltage: 1-phase / 230V / 50Hz,3-phase / 400V / 50Hz
Performance curve
1 O
Specifications
Model Colour code curve ø Discharge bore mm Type of Fluid Max. Solid Handling mm Max. PH Value Max. Capacity l/min Max. Head m Motor output kW Phase / Voltage
50TM2.4S 50mm Sewage 10 3-10 290 12 0,4 1-phase / 230V / 50Hz
50TMA2.4S   50mm Sewage 10 3-10 290 12 0,4 1-phase / 230V / 50Hz
50TM2.75 50mm Sewage 10 3-10 350 15 0,75 3-phase / 400V / 50Hz
ø Discharge bore mm 50mm
Type of Fluid Sewage
Max. Solid Handling mm 10
Max. PH Value 3-10
Max. Capacity l/min 290
Max. Head m 12
Motor output kW 0,4
Phase / Voltage 1-phase / 230V / 50Hz
ø Discharge bore mm 50mm
Type of Fluid Sewage
Max. Solid Handling mm 10
Max. PH Value 3-10
Max. Capacity l/min 290
Max. Head m 12
Motor output kW 0,4
Phase / Voltage 1-phase / 230V / 50Hz
ø Discharge bore mm 50mm
Type of Fluid Sewage
Max. Solid Handling mm 10
Max. PH Value 3-10
Max. Capacity l/min 350
Max. Head m 15
Motor output kW 0,75
Phase / Voltage 3-phase / 400V / 50Hz
General
ø Discharge bore mm 50mm
Discharge Connection Inside thread, flange
Pumping Fluid
Type of Fluid Sewage
Temperature 0-40°C
Max. Solid Handling mm 10
Max. PH Value 3-10
Max. Capacity l/min 290 - 350
Max. Head m 12 - 15
Pump
Components
Impeller Vortex impeller
Bearings Shielded ball bearings
Mechanical Seal Dual mechancial seal in oil bath
Material
Impeller Glass fibre reinforced plastic
Casing Glass fibre reinforced plastic
Pump Body Titanium
Mechanical Seal Silicon Carbide
Motor
Motor output kW 0,4 - 0,75
Starting method condensor, direct online
Type, Poles Induction motor, 2 poles, IP68
Insulation Insulation class E
Phase / Voltage 1-phase / 230V / 50Hz, 3-phase / 400V / 50Hz
r.p.m. 2792 - 2812
Motor Protector (built-in) Circle thermal cut-out
Rated Current 1.90 - 3.10
Material
Shaft Titanium
Cable H07RN8-F 3C*1.0mm², NSSHÖU 4C*1.5mm²
Cable Length 10m
Others
Dry Weight Kg 6.70 - 7.80
Pressure Resistance max. 20m
Dimensions - in mm
W1: lowest running water level
  • 50TMA2.4S
W1: lowest running water level
  • 50TM2.4S
  • 50TM2.75
ModelAA1A2BB1DD1D2FL1FL2HW1
50TM2.4S23611581102901628676--360110
50TMA2.4S23611581102-1737697115607374-
50TM2.7523611581102901628676--374110

The TM-series is a submersible titanium portable pump designed for handling seawater. It is made of titanium and resin. Since titanium has a superb corrosion resistance against seawater, it is suitable for various applications where seawater is used. Liquid paraffin is used for the lubricating oil, which makes it ideal for saltwater aquaculture.

Pump Discharge 032-165-29
2" Hose Coupling

2" discharge with suitable connection for hose coupling

Oil Leakage Sensor TSS-TEG-08
TSS Seal Oil Sensor M8 (10m)

Externally mounted leak sensors for water detection inside of oil chamber. Please note, an additional relay e.g. finder needs to be installed.

Motor Protection Plugs 56103000tu
Motor Protecton Plug 230V w/z hand-automatic (on-off)
Specifications
Amperage Control 3,0A
Cable Gland 2 x M16
IP 44

switch: OFF-ON (0-I) protection 3A 2x cable glands M16, for use of external float switch Overload Protection: Automatically disconnects the motor in case of excessive current draw, preventing overheating and damage.

Guide Rail Fitting System XITOK4P
TOK4-P (For Vancs, TM/T, PU/A)

TOK type guide-rail fittings are fiberglass reinforced smaller guide-rail fitting accessories, specially designed for smaller Tsurumi pumps.
Pump Discharge 032-165-29
2" Hose Coupling

2" discharge with suitable connection for hose coupling

Cable repair set 061-TEG-05
Cable Repair Kit for 001-012-44 Cabtyre Cable Set (10m) H07RN8

Cable repair set which allows you to repair a broken cable on site by yourself.
Pump Discharge 032-165-29
2" Hose Coupling

2" discharge with suitable connection for hose coupling

Oil Leakage Sensor TSS-TEG-08
TSS Seal Oil Sensor M8 (10m)

Externally mounted leak sensors for water detection inside of oil chamber. Please note, an additional relay e.g. finder needs to be installed.

Motor Protection Plugs 547150253tu
Plug CEE 16A
Specifications
Amperage Control 1,6A - 2,5A
Cable Gland M25
IP 44

Rotary lever actuation, motor protection with adjustment of the respective rated current, with phase turner and rotary field control, cable gland, Overload Protection: Automatically disconnects the motor in case of excessive current draw, preventing over

Motor Protection Plugs 547250253tu
Plug CEE 32 A
Specifications
Amperage Control 1,6A - 2,5A
Cable Gland M32
IP 44

Rotary lever actuation, motor protection with adjustment of the respective rated current, with phase turner and rotary field control, cable gland, Overload Protection: Automatically disconnects the motor in case of excessive current draw, preventing over

Motor Protection Plugs 5571501600tu
Plug with float connection CEE 16A
Specifications
Amperage Control 1,6A - 2,4A
Cable Gland M25
IP 44

Rocker switch ON/OFF (HAND/AUTO), motor protection with adjustment of the respective rated current, contactor max. 7,5kW, with phase inverter, operating display and rotation field check cable gland for float switch and Power cable Overload Protection: Aut

Motor Protection Plugs 5572501600tu
Plug with float connection CEE 32A
Specifications
Amperage Control 1,6A - 2,4A
Cable Gland M32
IP 44

Rocker switch ON/OFF (HAND/AUTO), motor protection with adjustment of the respective rated current, contactor max. 7,5kW, with phase inverter, operating display and rotation field check cable gland for float switch and Power cable Overload Protection: Aut

Motor Protection Plugs 587150253
CEE MS PW Stecker 16/5 6h 1.6-2.5A DFK IP67
Specifications
Amperage Control 1,6A - 2,5A
Cable Gland M25
IP 67

Rotary lever actuation, motor protection with adjustment of the respective rated current, with phase turner and rotary field control, cable gland, Overload Protection: Automatically disconnects the motor in case of excessive current draw, preventing over

Motor Protection Plugs 587250253
CEE MS PW Stecker 32/5 6h 1.6-2.5A DFK IP67
Specifications
Amperage Control 1,6A - 2,5A
Cable Gland M32
IP 67

Rotary lever actuation, motor protection with adjustment of the respective rated current, with phase turner and rotary field control, cable gland, Overload Protection: Automatically disconnects the motor in case of excessive current draw, preventing over

Guide Rail Fitting System XITOK4P
TOK4-P (For Vancs, TM/T, PU/A)

TOK type guide-rail fittings are fiberglass reinforced smaller guide-rail fitting accessories, specially designed for smaller Tsurumi pumps.

Cable repair set 061-TEG-06
Cable Repair Kit for 001-TEG-31 Cabtyre Cable Set (20m) H07RN-F4Cx1,5mm2 and M01-TEG-31 Cable NSSHOEU 4G*1,5 mm2 (20m)

Cable repair set which allows you to repair a broken cable on site by yourself.