Titanium is used in all the wet metal parts of the TM pumps. Titanium has a far stronger oxide film on its surface than stainless steel does. This prevents the pumps from being corroded in the seawater which has a very high chlorine ion concentration.
Model | Colour code curve | ø Discharge bore mm | Type of Fluid | Max. Solid Handling mm | Max. PH Value | Max. Capacity l/min | Max. Head m | Motor output kW | Phase / Voltage |
---|---|---|---|---|---|---|---|---|---|
50TM2.4S |
1
|
50mm | Sewage | 10 | 3-10 | 290 | 12 | 0,4 | 1-phase / 230V / 50Hz |
50TMA2.4S | 50mm | Sewage | 10 | 3-10 | 290 | 12 | 0,4 | 1-phase / 230V / 50Hz | |
50TM2.75 |
2
|
50mm | Sewage | 10 | 3-10 | 350 | 15 | 0,75 | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 50mm |
Type of Fluid | Sewage |
Max. Solid Handling mm | 10 |
Max. PH Value | 3-10 |
Max. Capacity l/min | 290 |
Max. Head m | 12 |
Motor output kW | 0,4 |
Phase / Voltage | 1-phase / 230V / 50Hz |
ø Discharge bore mm | 50mm |
Type of Fluid | Sewage |
Max. Solid Handling mm | 10 |
Max. PH Value | 3-10 |
Max. Capacity l/min | 290 |
Max. Head m | 12 |
Motor output kW | 0,4 |
Phase / Voltage | 1-phase / 230V / 50Hz |
ø Discharge bore mm | 50mm |
Type of Fluid | Sewage |
Max. Solid Handling mm | 10 |
Max. PH Value | 3-10 |
Max. Capacity l/min | 350 |
Max. Head m | 15 |
Motor output kW | 0,75 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 50mm |
---|---|
Discharge Connection | Inside thread, flange |
Type of Fluid | Sewage |
---|---|
Temperature | 0-40°C |
Max. Solid Handling mm | 10 |
Max. PH Value | 3-10 |
Max. Capacity l/min | 290 - 350 |
Max. Head m | 12 - 15 |
Impeller | Vortex impeller |
---|---|
Bearings | Shielded ball bearings |
Mechanical Seal | Dual mechancial seal in oil bath |
Impeller | Glass fibre reinforced plastic |
---|---|
Casing | Glass fibre reinforced plastic |
Pump Body | Titanium |
Mechanical Seal | Silicon Carbide |
Motor output kW | 0,4 - 0,75 |
---|---|
Starting method | condensor, direct online |
Type, Poles | Induction motor, 2 poles, IP68 |
Insulation | Insulation class E |
Phase / Voltage | 1-phase / 230V / 50Hz, 3-phase / 400V / 50Hz |
r.p.m. | 2792 - 2812 |
Motor Protector (built-in) | Circle thermal cut-out |
Rated Current | 1.90 - 3.10 |
Shaft | Titanium |
---|---|
Cable | H07RN8-F 3C*1.0mm², NSSHÖU 4C*1.5mm² |
Cable Length | 10m |
Dry Weight Kg | 6.70 - 7.80 |
---|---|
Pressure Resistance | max. 20m |
Model | A | A1 | A2 | B | B1 | D | D1 | D2 | FL1 | FL2 | H | W1 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
50TM2.4S | 236 | 115 | 81 | 102 | 90 | 162 | 86 | 76 | - | - | 360 | 110 |
50TMA2.4S | 236 | 115 | 81 | 102 | - | 173 | 76 | 97 | 115 | 607 | 374 | - |
50TM2.75 | 236 | 115 | 81 | 102 | 90 | 162 | 86 | 76 | - | - | 374 | 110 |
The TM-series is a submersible titanium portable pump designed for handling seawater. It is made of titanium and resin. Since titanium has a superb corrosion resistance against seawater, it is suitable for various applications where seawater is used. Liquid paraffin is used for the lubricating oil, which makes it ideal for saltwater aquaculture.