GY | 3-phase / 1-phase / 50Hz

Grinder pumps, part of a high head wastewater range of pumps. The grinder mechanism, with its stationary cutting ring and rotating blade, shredding the solids into small pieces. ATEX version available upon request.

Technical Data

  • ø Discharge bore mm: 50
  • Type of Fluid: Sewage
  • Max. PH Value: 5-9
  • Max. Capacity l/min: 195 - 512
  • Max. Head m: 20.40 - 68
  • Motor output kW: 0,9 - 9,5
  • Phase / Voltage: 1-phase / 230V / 50Hz,3-phase / 400V / 50Hz
Performance curve
1
2
Specifications

Model Colour code curve ø Discharge bore mm Type of Fluid Max. PH Value Max. Capacity l/min Max. Head m Motor output kW Phase / Voltage
free standing with guide rail fitting
50GY2.9 TOS50GY2.9 50 Sewage 5-9 330 20.80 0,9 3-phase / 400V / 50Hz
50GY21.1S TOS50GY21.1S 50 Sewage 5-9 312 20.40 1,1 1-phase / 230V / 50Hz
50GY21.5S TOS50GY21.5S 50 Sewage 5-9 195 30.50 1,5 1-phase / 230V / 50Hz
50GY21.8S TOS50GY21.8S 50 Sewage 5-9 360 32.10 1,8 1-phase / 230V / 50Hz
50GY21.6 TOS50GY21.6 50 Sewage 5-9 198 31 1,6 3-phase / 400V / 50Hz
50GY21.9 TOS50GY21.9 50 Sewage 5-9 353 33.20 1,9 3-phase / 400V / 50Hz
50GY23.1 TOS50GY23.1 50 Sewage 5-9 462 35 3,1 3-phase / 400V / 50Hz
50GY23.1H TOS50GY23.1H 50 Sewage 5-9 398 38.30 3,1 3-phase / 400V / 50Hz
50GY23.7 TOS50GY23.7 50 Sewage 5-9 355 46.70 3,7 3-phase / 400V / 50Hz
50GY24.4 TOS50GY24.4 50 Sewage 5-9 355 52 4,4 3-phase / 400V / 50Hz
50GYM26.4 TOS50GYM26.4 50 Sewage 5-9 512 42 6,4 3-phase / 400V / 50Hz
50GYM26.4H TOS50GYM26.4H 50 Sewage 5-9 512 52 6,4 3-phase / 400V / 50Hz
50GYM29.5 TOS50GYM29.5 50 Sewage 5-9 512 68 9,5 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 330
Max. Head m 20.80
Motor output kW 0,9
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 312
Max. Head m 20.40
Motor output kW 1,1
Phase / Voltage 1-phase / 230V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 195
Max. Head m 30.50
Motor output kW 1,5
Phase / Voltage 1-phase / 230V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 360
Max. Head m 32.10
Motor output kW 1,8
Phase / Voltage 1-phase / 230V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 198
Max. Head m 31
Motor output kW 1,6
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 353
Max. Head m 33.20
Motor output kW 1,9
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 462
Max. Head m 35
Motor output kW 3,1
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 398
Max. Head m 38.30
Motor output kW 3,1
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 355
Max. Head m 46.70
Motor output kW 3,7
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 355
Max. Head m 52
Motor output kW 4,4
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 512
Max. Head m 42
Motor output kW 6,4
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 512
Max. Head m 52
Motor output kW 6,4
Phase / Voltage 3-phase / 400V / 50Hz

ø Discharge bore mm 50
Type of Fluid Sewage
Max. PH Value 5-9
Max. Capacity l/min 512
Max. Head m 68
Motor output kW 9,5
Phase / Voltage 3-phase / 400V / 50Hz
General
ø Discharge bore mm 50
Discharge Connection Flange DIN/ANSI DN50 (PN10)
ATEX available Yes
Pumping Fluid
Type of Fluid Sewage
Temperature 0-35°C
Max. PH Value 5-9
Max. Capacity l/min 195 - 512
Max. Head m 20.40 - 68
Pump
Components
Impeller Grinder mechanism
Bearings Shielded ball bearings
Mechanical Seal Inside/outside mechancial seal
Material
Impeller Grey iron casting EN-GJL-250
Casing Grey iron casting EN-GJL-250
Motor
Motor output kW 0,9 - 9,5
Type, Poles Induction motor, 2 poles, IP68
Insulation Insulation class H
Phase / Voltage 1-phase / 230V / 50Hz, 3-phase / 400V / 50Hz
r.p.m. 2840 - 2900
Motor Protector (built-in) Miniature protector
Rated Current 2,5 - 18,8
Material
Shaft Stainless steel EN-X5CrNiMo17-12-2
Cable H07RN8-F PLUS 6G1,5, H07RN-F 4G1,5, H07RN-F 7G1,5, H07RN8-F PLUS 10G1,5, H07RN8-F PLUS 12G1,5
Cable Length 10m
Others
Dry Weight Kg 31.70 - 110.32
Pressure Resistance max. 20m
Dimensions in mm:
W1: lowest running water level
  • 50GY21.5S
  • 50GY21.8S
  • 50GY21.9
  • 50GY21.6
  • 50GY23.1
  • 50GY23.7
  • 50GY24.4
  • 50GY23.1H
W1: lowest running water level
  • 50GY21.1S
  • 50GY2.9
W1: lowest running water level
  • 50GYM26.4
  • 50GYM26.4H
  • 50GYM29.5
ModelABG
50GY2.9406--
50GY21.1S406496-
50GY21.5S468618223
50GY21.8S468618223
50GY21.6468618-
50GY21.9468618223
50GY23.1505655223
50GY23.1H505655223
50GY23.7545695250
50GY24.4545695250
50GYM26.4771790-
50GYM26.4H771790-
50GYM29.5844862-
Dimensions - guide rail fitting type in mm:
  • 50GY21.1S
  • 50GY21.5S
  • 50GY21.8S
  • 50GY21.9
  • 50GY21.6
  • 50GY23.1
  • 50GY23.7
  • 50GY24.4
  • 50GY23.1H
  • 50GY2.9
W1: lowest running water level
  • 50GYM26.4
  • 50GYM26.4H
  • 50GYM29.5
W1: lowest running water level
ModelBCDEFG
50GY2.9-172560457360190
50GY21.1S-172560457360190
50GY21.5S-183630504407223
50GY21.8S-183630504407223
50GY21.6-183630504407223
50GY21.9-183630504407223
50GY23.1-183672504407223
50GY23.1H-183672504407223
50GY23.7-187706527429250
50GY24.4-187706527429250
50GYM26.4790-----
50GYM26.4H790-----
50GYM29.5862-----

GY

647.2 KB | PDF English

Download

The GY-series is a submersible grinder pump ideal for sewage disposal with small pipe cross-sections, large delivery heads with relatively low delivery rates, pressure drainage systems in topographically difficult areas. GY breaks up solids carried along in fractions of a second, so that plastic pipes with cross-sections from 1½" are already sufficient for the pipelines. In this way, the costs for the use of materials and the laying of sewage systems can be significantly reduced. ATEX available.