Three-phase drainage pumps equipped with dual impellers capable of very high heads. Cast iron construction gives exceptional performance in harsh operating conditions. With this design the base is small, which enables good positioning in confined spaces.
Model | Colour code curve | ø Discharge bore mm | Type of Fluid | Max. Solid Handling mm | Max. dry matter % | Max. PH Value | Max. Capacity l/min | Max. Head m | Motor output kW | Phase / Voltage |
---|---|---|---|---|---|---|---|---|---|---|
LH23.0W |
1
|
50 | Drainage | 6 | 3-5 | 5-9 | 600 | 39 | 3,0 | 3-phase / 400V / 50Hz |
LH25.5W |
2
|
50 | Drainage | 6 | 3-5 | 5-9 | 490 | 65 | 5,5 | 3-phase / 400V / 50Hz |
LH311W |
3
|
80 | Drainage | 8.50 | 3-5 | 5-9 | 700 | 81 | 11,0 | 3-phase / 400V / 50Hz |
LH322W |
4
|
80 | Drainage | 8.50 | 3-5 | 5-9 | 940 | 102 | 22,0 | 3-phase / 400V / 50Hz |
LH430W |
5
|
100 | Drainage | 8.50 | 3-5 | 5-9 | 1230 | 123 | 30,0 | 3-phase / 400V / 50Hz |
LH4110W |
6
|
100 | Drainage | 8 | 3-5 | 5-9 | 2000 | 216 | 110,0 | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 50 |
Type of Fluid | Drainage |
Max. Solid Handling mm | 6 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 600 |
Max. Head m | 39 |
Motor output kW | 3,0 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 50 |
Type of Fluid | Drainage |
Max. Solid Handling mm | 6 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 490 |
Max. Head m | 65 |
Motor output kW | 5,5 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 80 |
Type of Fluid | Drainage |
Max. Solid Handling mm | 8.50 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 700 |
Max. Head m | 81 |
Motor output kW | 11,0 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 80 |
Type of Fluid | Drainage |
Max. Solid Handling mm | 8.50 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 940 |
Max. Head m | 102 |
Motor output kW | 22,0 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 100 |
Type of Fluid | Drainage |
Max. Solid Handling mm | 8.50 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 1230 |
Max. Head m | 123 |
Motor output kW | 30,0 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 100 |
Type of Fluid | Drainage |
Max. Solid Handling mm | 8 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 2000 |
Max. Head m | 216 |
Motor output kW | 110,0 |
Phase / Voltage | 3-phase / 400V / 50Hz |
ø Discharge bore mm | 50 - 100 |
---|---|
Discharge Connection | JIS 20K Flange, Threaded flange |
Type of Fluid | Drainage |
---|---|
Temperature | 0-40°C |
Max. Solid Handling mm | 6 - 8.50 |
Max. dry matter % | 3-5 |
Max. PH Value | 5-9 |
Max. Capacity l/min | 490 - 2000 |
Max. Head m | 39 - 216 |
Impeller | Closed type impeller |
---|---|
Bearings | Shielded ball bearings |
Mechanical Seal | Dual mechancial seal in oil bath |
Impeller | Chromium iron casting |
---|---|
Casing | Ductile iron casting EN-GJS-450-10, Grey iron casting EN-GJL-200 |
Pump Body | Steel , Structured Steel, Carbon Steel |
Mechanical Seal | Silicon Carbide |
Motor output kW | 3,0 - 110,0 |
---|---|
Starting method | direct online , star/delta |
Type, Poles | Induction motor, 2 poles, IP68 |
Insulation | Insulation class B, Insulation class F |
Phase / Voltage | 3-phase / 400V / 50Hz |
r.p.m. | 2820 - 2965 |
Motor Protector (built-in) | Circle thermal cut-out, Miniature protector |
Rated Current | 6.50 - 209 |
Frame | Grey iron casting EN-GJL-200 |
---|---|
Shaft | Stainless steel EN-X30Cr13 |
Cable | NSSHÖU 4C*1.5mm², NSSHÖU 4C*2.5mm², NSSHÖU 4C*4.0mm², NSSHÖU 4C*10mm², NSSHÖU 7C*35mm²/2C*2.5mm², NSSHÖU(3C*35mm²,3*16mm²/3E,2*2,5ST);NSSHÖU (3C*35mm², 3*16mm²/3E) |
Cable Length | 20m |
Dry Weight Kg | 46 - 1270 |
---|---|
Pressure Resistance | max. 50m |
Model | B | D | D1 | W1 | d |
---|---|---|---|---|---|
LH23.0W | 591 | 185 | - | 150 | 50 |
LH25.5W | 750 | 240 | - | 170 | 50 |
LH311W | 1030 | 270 | - | 200 | 80 |
LH322W | 1234 | 330 | - | 300 | 80 |
LH430W | 1375 | 330 | - | 300 | 100 |
LH4110W | 1825 | 616 | 592 | 380 | 100 |
The LH-W-series is a three-phase cast iron extra high head drainage pump having dual impellers. Installations in narrow spaces like deep wells are no problem thanks to its slim design. The center flange construction assures a stable installation even if it is fixed by the discharge pipe.*1 The top discharge, flow-thru design provides maximum motor cooling efficiency allowing continuous operation at low water levels and extended dry-run capability. The pump incorporates seal pressure relief ports that prevent the pumping pressure from applying to the shaft seal.*2
*1 excluding LH4110W
*2 excluding LH23.0W
Ash from the recycling process is stored on the premises of a steel recycling company. Recycled water is used to cool the ash. This drainage water must be sprayed in large quantities onto the hot ash via a sprinkler system. The sprinkler system itself operates at a system pressure of 3 to 4 bar.