The project:

Reconstruction of a well, installation and adaptation of a new pump


Customer:

Eternit AG


Performing company:

Haugrund und Runte Elektromaschinenbau GmbH


Project lead at Tsurumi:

Mr. Jürgen Rohring (Regional Sales Lead Construction NRW)


The problem:

Rebuilding of a well system.

Measure: Replacement of three small pumps of "lumberyard quality".

The use of a higher-quality product should permit longer service life and adjustment of each water fountain.


The solution:

Replacement of the three pumps with a Tsurumi model 50UT2.75S (750W, 230V) submersible pump.

This is a portable, rugged pump in a cast iron variant with a vortex impeller.

The pump was modified in such a way that three fountain nozzles can be operated with the option of controlling each water fountain individually or all together.

In het geval van schurend en corrosief gebruik, zullen bepaalde componenten van nature sneller verslijten. Met betrekking tot bovenstaande toepassing kan slijtage met name optreden in de waaier, de roerder, het zuigdeksel, de asbus, de oliering, de mechanische asafdichting,het pomphuis, de zuigkorf, de motorbehuizing en de afvoerkoppeling. Afhankelijk van de werkingsomstandigheden kan de levensduur van die onderdelen aanzienlijk variëren en kan deze korter zijn dan de wettelijke garantieperiode.