Sewage treatment, hotel complex, Croatia

The Project:


Treatment of waste water from a hotel complex with a total capacity of 600 persons, Dubrovnik, Croatia


Executing companies:

ISEA d.o.o., Rijeka, Croatia

VIS-Trgovina d.o.o.


The problem:


Hotel complex not connected to public sewage system; sewage disposal was formerly via awaste-water pipe direct and untreated into the Adriatic. Complex is used seasonally, especially in tourism season; otherwise it is little used. Previously there were problems with compressed aeration systems, since polyethyline pipes melted (due to high temperature of air underpressure), plus noise (systems situated directly by house and hotel, with noise-generating compressors).


The solution:


Connection to a small modular sewage works in polyethylene tanks (no connection to mains sewage necessary). A total of 6 Tsurumi submersible aerators, 0.75 kW each, were fitted in the biological water treatment section. Seasonal use possible without problems; whenout of use, the aerators simply remain in the tanks. No more melted pipes, because the self-drawn air is at the ambient temperature. No noise problem any more; the system operates very quietly.

In caso di utilizzo di prodotti abrasivi o corrosivi, alcuni componenti saranno naturalmente soggetti a maggiore usura. Riguardo alla suddetta applicazione, l'usura può avvenire principalmente nella girante, nell'agitatore, nella piastra aspirante, nel manicotto dell'albero, nell'anello di lubrificazione, nella tenuta meccanica, nel corpo della pompa, nel filtro, nel corpo del motore e nel raccordo di scarico. A seconda delle condizioni di lavoro, la durata di queste parti può variare significativamente ed essere inferiore al periodo legale di garanzia.
A questo proposito, si prega di prestare attenzione ai nostri termini e condizioni generali, che possiamo anche inviare per posta elettronica su richiesta.