Direkt zum Inhalt | Direkt zur Navigation
Sei qui:

Zagreb Arena, Croatia

The project:


Construction of the Zagreb Arena for the 2009 Handball World Championship


Executing companies:

Fngra d.d. Zagreb

TriGranit Zagreb d.o.o.

GIP Pionir d.o.o.

VIS-Trgovina d.o.o.


The problem:


The subzero-grain sludge originating from the gravel washing plant which has collected in the used water pond had to be pumped off.


Our solution:


By the application of a high-performance Tsurumi submersible waste water pump of Type KRS822 with an additionally attached flushing device, which was supplied with fresh water by means of a separate high-pressure pump, the settled sludge was agitated and was pumped off in a highly concentrated condition. The advantage of this type of pump is the low rotational speed of 1450 rpm affording a considerably longer service life.

In caso di utilizzo con liquidi abrasivi o corrosivi, alcuni componenti saranno naturalmente soggetti a maggiore usura. Nello specifico l'usura può avvenire principalmente nella girante, nell'agitatore, nel piatto di usura, nel manicotto dell'albero, nell'anello di lubrificazione, nel dispositivo di tenuta, nel corpo della pompa, nel filtro, nel corpo del motore e nel raccordo di scarico. A seconda delle condizioni di lavoro, la durata di queste parti può variare significativamente ed essere inferiore al periodo legale di garanzia.
Si prega di vedere in merito le nostre condizioni generali, che possiamo inviarvi per posta elettronica su richiesta.