Richmann-Muller, Belgium
The project:
Replacement of a defective wastewater pump station in a residential house.
Executing company:
Marine Motors & Pumps NV (Tsurumi partner)
The problem:
Pumping out wastewater from a collector shaft of the building. The shaft covers have a max. diameter of just 347mm.
The solution:
Installation of two type 80U2.75 sewage pumps with an open type impeller.
A stationary installation with guide pipes was chosen.
The regulation of the pumps is carried out with a low-maintenance and low-wear pneumatic level control system.
U slučaju abrazivnih i korozivnih primjena, normalno je da će se u određenim komponentama dogoditi snažnije trošenje. S obzirom na gornju primjenu trošenje se može odvijati uglavnom u radnom kolu, miješalici, usisnoj ploči, rukavcu osovine, uljnom prstenu, mehaničkoj brtvi, kućištu pumpe, cjedilu, kućištu motora i ispusnoj spojki. Ovisno o radnim uvjetima vijek trajanja tih dijelova može značajno varirati i može biti kraći od pravnog zakonskog razdoblja.
S obzirom na to pridavajte pažnju našim
općim uvjetima koje vam također šaljemo e-poštom na zahtjev.