Direkt zum Inhalt | Direkt zur Navigation
Vi ste ovdje:

Sewage treatment, hotel complex, Croatia

The Project:


Treatment of waste water from a hotel complex with a total capacity of 600 persons, Dubrovnik, Croatia


Executing companies:

ISEA d.o.o., Rijeka, Croatia

VIS-Trgovina d.o.o.


The problem:


Hotel complex not connected to public sewage system; sewage disposal was formerly via awaste-water pipe direct and untreated into the Adriatic. Complex is used seasonally, especially in tourism season; otherwise it is little used. Previously there were problems with compressed aeration systems, since polyethyline pipes melted (due to high temperature of air underpressure), plus noise (systems situated directly by house and hotel, with noise-generating compressors).


The solution:


Connection to a small modular sewage works in polyethylene tanks (no connection to mains sewage necessary). A total of 6 Tsurumi submersible aerators, 0.75 kW each, were fitted in the biological water treatment section. Seasonal use possible without problems; whenout of use, the aerators simply remain in the tanks. No more melted pipes, because the self-drawn air is at the ambient temperature. No noise problem any more; the system operates very quietly.

U slučaju abrazivnih i korozivnih primjena, normalno je da će se u određenim komponentama dogoditi snažnije trošenje. S obzirom na gornju primjenu trošenje se može odvijati uglavnom u radnom kolu, miješalici, usisnoj ploči, rukavcu osovine, uljnom prstenu, mehaničkoj brtvi, kućištu pumpe, cjedilu, kućištu motora i ispusnoj spojki. Ovisno o radnim uvjetima vijek trajanja tih dijelova može značajno varirati i može biti kraći od pravnog zakonskog razdoblja.
S obzirom na to pridavajte pažnju našim općim uvjetima koje vam također šaljemo e-poštom na zahtjev.