Direkt zum Inhalt | Direkt zur Navigation
Vous êtes ici :

Rupp gravel plant, Dillingen, Germany

The project:


Preparation/clarification of rinse water from gravel processing


Executing company:

Josef Rupp GmbH&Co. KG


The problem:


The condensed slurry from the clarification tower is pumped into the buffer silos of the chamber filter press. The consistency of the medium ranges from fluid to a thickly flowing mud. Lime is added to the mud for conditioning.


Our solution:


The high proportion of abrasive sediments could not be pumped satisfactorily using the pumps in use until now. The result was a high degree of wear and replacement part costs.

En cas d'utilisation abrasive et corrosive, une usure plus important se manifestera naturellement dans certains composants. En rapport avec l'application ci-dessus, l'usure peut principalement apparaître au niveau de la turbine, de l'agitateur, du panneau d'aspiration, de la chemise d'arbre, de la bague de graissage, du joint mécanique, du carter de la pompe, du filtre, du carter du moteur et du couple de décharge. Selon les conditions de travail, la durée de vie de ces pièces peut varier de manière significative et peut être inférieure à la période légale de garantie.
À cet égard, veuillez tenir compte de nos conditions générales que nous pouvons également vous envoyer par e-mail si vous le souhaitez.