Pump Testing Days, Fürth, Germany

The Project:


Pump testing days at the premises of Gebr. Mayer, electrical and mechanical testing


Companies involved:

Gebr. Mayer GmbH&Co. KG, Fürth


The Problem:


Testing the pumps in accordance with the health and safety regulations at work "BGV A3" applied for machinery with changing locations.


Our Support


Testing the pumps at the premises of the company Gebr. Mayer within the framework of the on-site standardization day. Electrical testing with the aid of a calibrated Secutester, mechanical testing (oil, parts subject to wear, cables). Once the tests had been successfully passed, the pump was issued with a test sticker for the next six months. Cable repairs were carried out on the spot, as was the replacement of the impeller, the shaft protection sleeve, the lip sealing ring, and the wear plate.

En cas d'utilisation abrasive et corrosive, une usure plus important se manifestera naturellement dans certains composants. En rapport avec l'application ci-dessus, l'usure peut principalement apparaître au niveau de la turbine, de l'agitateur, du panneau d'aspiration, de la chemise d'arbre, de la bague de graissage, du joint mécanique, du carter de la pompe, du filtre, du carter du moteur et du couple de décharge. Selon les conditions de travail, la durée de vie de ces pièces peut varier de manière significative et peut être inférieure à la période légale de garantie.