The Project:


Construction of a waste-water channel in Belgrade with 1500mm diameter


Executing companies:

Ferbild d.o.o., Belgrade

Vedir-Impex d.o.o.


The problem:


Laying of pipes with 1500mm diameter at a depth of 8m. Proximity to the Danube means that groundwater occurs at only 3m depth. Accordingly, the construction site was 5m below the groundwater level along its entire length. Since the ground contains a high proportion of grit, difficulties were encountered in lowering the groundwater.


The solution:


12 wells sunk to depths of up to 25m were drilled parallel to the new canal. At this depth the ground consists of shingle and groundwater could be pumped with ease. 15 Tsurumi pumps were used, of types KTZ611,KTZ35.5, KTZ22.2, KTVE35.5 and LH615.

En el caso de utilizarse con productos abrasivos y corrosivos, determinados componentes sufrirán un desgaste más intenso de forma natural. En relación con la aplicación indicada más arriba, dicho desgaste se puede producir principalmente en el impulsor, el agitador, la placa de succión, el casquillo del eje, el anillo de engrase, el sello mecánico, la carcasa de la bomba, el colador, la carcasa del motor y el acoplamiento de descarga. En función de las condiciones de trabajo, la vida útil de estas piezas puede variar significativamente y puede ser inferior al período de garantía legal.
En este sentido, son de aplicación nuestros términos y condiciones generales, que también le podemos enviar por correo electrónico si lo solicita.