Direkt zum Inhalt | Direkt zur Navigation
You are here:

Fountain, Munich, Germany

The Project:

Fountain system at the Insel Mühle hotel in Munich


Contractor:

Company Plötz


Tsurumi support:

Christian Kulik (Field Sales)


The Problem:

Use of drainage-water pumps to supply a fountain. A clean water pump cannot be used as the pumped water is a dirty.


The Solution:

Use of a Tsurumi NK2–22 drainage pump (2.2 kW, 230 V) with a pumping head of 24 m and a type KTZ23.7 (3.7 kW, 400 V) with a pumping head of 37 m.

In the event of abrasive and corrosive utilization, stronger wear and tear will take place naturally in certain components. With regards to the above application wear and tear can take place mainly in impeller, agitator, suction plate, shaft sleeve, oil ring, mechanical seal, pump casing, strainer, motor casing and discharge coupling. Depending on the working conditions the lifetime of those parts might vary significantly and can be shorter than the legal warranty period.
In this regard, please pay attention to our general terms and conditions that we also send to you by mail on request.