How to Identify When a Pump Needs Maintenance

Published on 07.10.2026

Tsurumi pumps are designed to perform reliably under the most demanding conditions. However, long operating hours, abrasive materials, mineral-rich water, corrosive liquids and changing operating conditions can all affect pump performance over time. Regular maintenance helps identify potential problems early, minimise unplanned downtime and extend service life. Recognising the warning signs of pump failure allows operators to take action before minor issues develop into major breakdowns.


Here are five key indicators that a pump may need inspection or maintenance:


1. Wear or Damage to the Impeller

Visible wear or damage to the impeller can indicate that a pump is operating under excessive stress. Common causes include:

  • Pumping abrasive solids that wear down internal components
  • Operating outside the recommended pump performance curve
  • Handling liquids that are incompatible with the pump's materials
  • Excessive cavitation or other operating conditions that place undue stress on components

Regular inspections help detect impeller damage before it significantly affects pump performance or leads to further mechanical problems.


2. Changes in Motor Current Draw

Monitoring the current draw of a submersible pump provides valuable information about its operating condition. Significant deviations from the expected current consumption may indicate a problem with the pump or the wider pumping system.

Possible causes include:

  • Blockages inside the pump or discharge line
  • Changes in the pumping system or operating conditions
  • Incorrect direction of pump rotation
  • Mechanical problems affecting motor performance

Monitoring current consumption can help identify irregularities at an early stage and support targeted troubleshooting.


3. Reduced Flow Rate

A noticeable reduction in flow rate is one of the most common signs that a submersible pump needs inspection. Possible causes include:

  • A worn impeller
  • A damaged suction plate
  • Blockages inside the pump or pipework
  • Changes in system operating conditions

A thorough inspection can help determine whether maintenance or the replacement of individual components will restore performance, or whether replacing the pump would be the more appropriate solution.


4. Incorrect Pump Head

If the actual pump head differs from the expected value, the relationship between flow rate and pressure may change, potentially causing the pump to operate outside its intended operating range.

Depending on the circumstances, this may result in:

  • Increased flow rates
  • Motor overload
  • Reduced pump efficiency
  • An increased risk of cavitation

If the measured head does not match the expected operating conditions, the entire pumping system should be checked. Potential causes include component wear, changes to the installation or application requirements that no longer match the pump's specifications.


5. Excessive Vibration

Unusual or excessive vibration can indicate mechanical problems that may eventually lead to pump failure. Possible causes include:

  • Damaged or bent shafts
  • Bearing failure
  • Impeller imbalance
  • Blockages in the pump or discharge system
  • Operation outside the recommended performance parameters

Excessive vibration should never be ignored. A qualified technician should inspect the pump to identify the underlying cause and prevent further damage.


Repair or Replace?

Once a problem has been identified, the next question is whether repairing the pump is worthwhile or whether replacement is the better option.


Repair may be the right choice when:

  • Wear or damage is limited to individual components
  • Suitable spare parts are available
  • The pump remains appropriate for the application
  • Repair costs are significantly lower than replacement costs

Replacement should be considered when:

  • Repairs are becoming increasingly frequent
  • The pump has reached the end of its expected service life
  • Operating costs continue to rise
  • The pump no longer meets the required flow rate or pressure
  • Changes in operating conditions mean the pump is no longer suitable for the application

A careful assessment of the pump's condition, operating requirements and total costs can help determine the most economical long-term solution.


Need Advice on Pump Maintenance or Replacement?

Identifying potential problems early can help reduce downtime, protect equipment and keep pumping systems operating efficiently.

Would you like to know more about maintaining your Tsurumi pump or deciding when replacement is necessary? Our team will be happy to help.

Contact us by email at sales@tsurumi.eu.